POCLAIN HYDRAULICS, s.r.o., spol. s r.o.

 

Installation: KingAir KAKIT3A300AF + KAAD328
(water> 99.9999%, impurities 99.98% to 0.01 micron, oil and aerosol up to 0.2g / m3)
Equipment: 3D Measurements on Hexagon Metrology (GIOBAL S)
Compressed air: screw compressor with air tank, metal air distribution
Original treatment of compressed air: microfiltration

Before
When the original air treatment was finished, the problem with residual oil persisted, which caused the problem only on the device itself in the table drives. Needed replacement of 3 months without problem solving.

After
Installation of KAKIT3 micro filtration with half-year testing. The result is a zero passage of the remaining oil to the end device without changing the filter cartridge (carbon filter, microfilter).

 

 


SIGNUM, spol. s r.o.

 

Installation: KingAir KA300AF + KAAD138
(drainage> 99.9999%, 99% impurity removal to 0.2 micron)
Equipment: waste incineration from industrial painting
Compressed air: screw compressor with air tank, air distribution
Original compressed air: refridgerant dryer after the compressor, compressed air line 50m

Original installation
The plastic air distribution behind the switchboard passes through the outdoor channel directly to the incinerator. When the outdoor temperature changes, the condensate freezes and the incinerator is shut down. During the winter season, there is a downtime every working day.

 

 


 

 Fol-Izol s.r.o.

Installation: KingAir KA300AF + KAAD328
(drainage > 99.9999%, 99% impurity removal to 0.2 micron)
Equipment: CYBERTORNIC Robotics s.r.o. with ALFA IN 100 A + machine burner
Compressed air: Two-piston ATMOS compressor with air tank, plastic air distribution
Original compressed air treatment: compressor dehumidifier and 2m in front of the plasma,
AT1000 filter before ALFA IN plasma and on the aggregate control valve with condensate drain.

Original installation

 The device is commonly used for piece cuts and small series. Main use of conventional steel. The two-piston compressor delivers compressed air that is contaminated with oil and water due to a large-volume immediate take-off at a pressure of 5.5 bar. The condensate is visible both in the compressor downstream and in front of the plasma. Since the existing desulphurizers are manual (vessel volume monitoring is required), the overflow occurs when the condensate enters the water-absorbing filter. (Customer’s note “Continuous problems and firing seal, does not fully fill the drain function”).

 The last fuse is a filter with a paper filter insert combined with a plasma pressure regulator. All of these filters and desulphurizers bring a basic problem to the system, as each device generates a pressure drop and reduces the pressure in the air distribution. The second problem is the low efficiency of the water drainage and due to oil contamination, the filter insert degrades. This is associated with increased operating and maintenance costs. For smaller companies, the costs associated with the treatment of compressed air are a major burden in the production and the adjustment itself is insufficient. If water and oil penetrate through filtration into the machine, the price of the cut piece increases (replacement of supplies).


Brany-ploty-kovo s.r.o.

 

Installation: KingAir KA300AF + KAAD328
(drainage> 99.9999%, 99% impurity removal to 0.2 micron)
Equipment: CYBERTORNIC Robotics s.r.o. with Hyperther powermax105 aggregate + machine burner
Compressed air: Two-piston air compressor, plastic air distribution
Original compressed air treatment: SATA filtering in front of the plasma, original filter supplied with the aggregate, and internal protective air filter (428351) in the unit.

Original installation

 

 

Contact

                                 WSPS Kft.
8096, Sukoró, Forrás u. 4.
Office-warehouse: 2045, Törökbálint,
Torbágy u. 13.
Magyarország
Mobil: +36 /20-512-7765
Email address: kingairinstall@gmail.com

Contact

WSPS Kft.

  • 8096, Sukoró, Forrás u. 4.
  • Office-warehouse: 2045, Törökbálint,
    Torbágy u. 13., Magyarország
  • Mobil: +36 /20-512-7765
  • Email: kingairinstall@gmail.com

Hosting provider

TeraHost Kft.

  • Address: Hungary, 2220, Vecsés,
    Kinizsi street 73.
  • Mobil: +36 30 690 9394
  • E-mail: info@teratarhely.hu
  • teratarhely.hu

Cookie Privacy Policy: Cookies help to provide our services. By using our services you consent to the use of cookies. Read more

Cookie use Cookies are short text files that the viewed websites place on your computer's browser. Cookies will not connect to your system and will not harm your files. Cookies may be "permanent" or "temporary" cookies. The permanent cookie is stored by the browser for a specified time, provided that the user does not delete it before, but the temporary cookie is not stored by the browser and will be automatically deleted by the browser. We use cookies to make our site work as efficiently as possible. Cookies allow a site to recognize recurring users and allow us to collect data about our users' behavior, for example, in which country you have joined our website, what browser software and operating system you are using, what is your IP address, what sites are considered on our website, which features he used. We will not collect personal identification data unless you voluntarily provide them. We use the data for further development of our website, for analyzing our visit, and for our advertising strategy. If you do not agree to place a cookie, you can do this by setting options (forbidden, revoked) in your browser. In this case, this may restrict or prevent the use of certain services.

Closure